 | | Supply |  | |  |  | | Rated voltage | 19.2 ... 35 V |
|
| |  |  | | Power loss | typ. 0.39 W per segment |
|
|
|
|
 | | Fieldbus interface |  |  |  | | Number of segments | 4 redundant |
|
|  |  | | Host-side | redundant general purpose host |
|
|  |  | | Terminator | 100 Ω integrated |
|
|
|
|
 | | Indicators/operating means |  |  |  | | Fault signal | VFC alarm output via connectors |
|
|
|
|
 | | Electrical isolation |  |  |  | | Fieldbus segment/Fieldbus segment | functional insulation acc. to IEC 62103, rated insulation voltage 50 Veff |
|
|  |  | | Fieldbus segment/Supply | functional insolation acc. to IEC 62103, rated insulation voltage 250 Veff |
|
|
|
|
 | | Directive conformity |  |  |  | | Electromagnetic compatibility |  |  |  |  | | Directive 2004/108/EC | EN 61326-1:2006 |
|
|
|
|
|
|
|
|
 | | Standard conformity |  |  |  | | Electromagnetic compatibility | NE 21:2006 |
|
|  |  | | Protection degree | IEC 60529 |
|
|  |  | | Fieldbus standard | IEC 61158-2 |
|
|  |  | | Shock resistance | EN 60068-2-27 |
|
|  |  | | Vibration resistance | EN 60068-2-6 |
|
|  |  | | Corrosion resistance | acc. to ISA-S71.04-1985, severity level G3 |
|
|
|
|
 | | Ambient conditions |  |  |  | | Ambient temperature | -40 ... 60 °C (-40 ... 140 °F) |
|
|  |  | | Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
|
|  |  | | Relative humidity | < 95 % non-condensing |
|
|  |  | | Shock resistance | 15 g , 11 ms |
|
|  |  | | Vibration resistance | 1 g , 10 ... 150 Hz |
|
|  |  | | Pollution Degree | max. 2, according to IEC 60664 |
|
|
|
|
 | | Mechanical specifications |  |  |  | | Connection type | plug with screw flange |
|
|  |  | | Core cross-section | 2.5 mm2 |
|
|  |  | | Housing material | Polycarbonate |
|
| | | | | | |
|
|
 | | Data for application in conjunction with hazardous areas |  |  |  | | Statement of conformity | TÜV 06 ATEX 553229 X |  |  |  | | Group, category, type of protection, temperature classification | II 3 G Ex nA II T4 |
|
|
|
|
|
|  |  | | Directive conformity |  |  |  |  | | Directive 94/9/EC | EN 60079-0:2006 , EN 60079-11:2007 , EN 60079-15:2006 |
|
|
|
|
|
|
|
|
 | | International approvals |  |  |  | | FM approval | CoC 3024816, CoC 3024816C |  |  |  | | Approved for | Class I, Division 2, Groups A, B, C, D, T4 / Class I, Zone 2, AEx/Ex nA IIC T4 |
|
|
|
|
|
|
|
|
 | | Certificates and approvals |  |  |  | | Marine approval | DNV A-10798 |
|
|
|
|